Incineration Systems
This unique Elliptical shape gives our incinerators a high structural strength and it provides a more efficient burning action with NO DEAD corners. It also features high temperature castable refractory, stainless steel stack, environmentally friendly clean smoke emission and automatic diesel or gas fired burners.
Incinerators are free standing, requiring only a concrete base, 240 volt power, fuel supply and weather shield. Pre-fired at works to operating temperature, making sure the unit is ready for full temperature operation upon installation & commissioning.
Installation/commissioning completed in DAYS not WEEKS.
Incinerator system design is determined by the product to be destroyed, hours of burning, loading requirements and degree of sophistication required.
We have a wide variety of Incinerator models on offer. We also custom build to customers specific needs. Some of the applications our Incinerators are used for:
- Hospital & Industrial Waste
- Animal & Poultry carcasses
- Municipal & Quarantine Waste
- Obsolete Drugs
- Security Documents
- Waste Oil
- Obsolete Currency
- Wood & Sawdust
- Sewage Plant Skimmings
KEY FEATURES:
- Exclusive Patent Elliptical Shape design accelerates waste reduction
- Dual Chambers creates environmentally friendly clean emissions
- High structural strength due to the Elliptical shape
- High temperature castable refractory
- Stainless steel stack
- Automatic diesel or gas fired burners
- Easy installation & maintenance
MK5.5 (Dual Chamber) 50kg/hr Mk 6 (Dual Chamber) 80kg/hr
MK6.5 - 100kg/hr MK7 - 120kg/hr MK7.5 - 150kg/h
Dual Chamber Semi Auto Loader Dual Chamber Counterbalance loading door Dual Chamber Semi Auto Loader
TECHNICAL SPECIFICATIONS | |||||||
MODEL |
MK |
MK |
MK |
MK |
MK |
MK |
MK |
Chamber |
Dual |
Dual |
Dual |
Dual |
Dual |
Dual |
Dual |
Burning Rate |
25 |
50 |
80 |
100 |
120 |
150 |
180 |
Loads per hr |
3 |
3 |
3 |
2 |
2 |
3 |
3 |
Loading Method |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Manual |
Power Req |
240v-50hz |
240v-50hz |
240v-50hz |
240v-50hz |
240v-50hz |
240v-50hz |
240v-50hz |
** Please note - Hydraulic Semi Automatic Loading available on request, require 3 phase power |
|||||||
Burner KW |
160kWo/o |
195kWo/o |
260kWo/o |
325 |
468 |
580 |
2200Mj x 2 |
FUEL TYPE |
|||||||
Diesel |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
LPG |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Natural Gas |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Various size Diesel tanks available on request for all models |
|||||||
MK 7, 7.5 & 8 available with Waste Oil Fuel option on request |
|||||||
DIMENSIONS |
|||||||
O/all Length (mm) |
2000 |
2300 |
2800 |
3100 |
3400 |
3600 |
4200 |
O/all Width (mm) |
1250 |
1100 |
1700 |
1800 |
2000 |
2000 |
2000 |
O/all Height (mm) |
2000 |
2300 |
2500 |
2500 |
2500 |
2500 |
2750 |
Hearth Area (mm) |
0.587 |
0.88 |
1.443 |
1.932 |
2.492 |
3.063 |
3.519 |
Primary Height |
1000 |
1200 |
1500 |
1500 |
1800 |
2240 |
1800 |
Volume |
0.6/0.4 |
1.0/0.6 |
2.1/1.3 |
3.0/1.5 |
4.5/2.5 |
5.0/3.0 |
6.3/3.8 |
Outside Circ |
3840 |
4485 |
5590 |
6328 |
7067 |
7713 |
8358 |
Ins/Ref (mm) |
75/75 |
75/75 |
75/75 |
75/75 |
90/85 |
90/85 |
100/100 |
Stack dia (mm) |
2.0/250 |
2.0/300 |
2.0/400 |
2.0/400 |
2.0/400 |
3.0/500 |
5.0/600 |
Weight (tonnes) |
2.5 |
3.5 |
5.5 |
7 |
9 |
16 |
19 |
PRIMARY CHAMBER OPERATING TEMPERATURE |
|||||||
Min |
750 |
750 |
750 |
750 |
750 |
750 |
750 |
Max |
950 |
950 |
950 |
950 |
950 |
950 |
950 |
SECONDARY CHAMBER OPERATING TEMPERATURE |
|||||||
Min |
950 |
950 |
950 |
950 |
950 |
950 |
950 |
Max |
1100 |
1100 |
1100 |
1100 |
1100 |
1100 |
1100 |